AWS δelta

Maintenance Videos

The following videos complement our module exchange service. Each video details the procedure of replacing a particular console assembly enabling you to replace a defective part with confidence.

Important notice:

Before attempting this procedure, please familiarise yourself with the instructions in full to ensure that you have sufficient time and technical skills to complete the procedure. If you would prefer an SSL engineer to perform the procedure, please contact your local SSL distributor office.

These instructions are intended for technically competent personnel. To reduce the risk of electric shock, do not perform the procedure unless you are competent to do so.

Electrostatic discharge (ESD)can damage electrical components, even if you cannot feel, see or hear it. Before starting work, grasp an exposed metal part of the console chassis with your bare hand to ground any static charge which you may have accumulated.

Switch off and disconnect the mains supply before removing any panels or modules.

Large capacitors such as those used in power supplies can continue to store dangerous voltages even if the console has been disconnected from the mains. To reduce the risk of electric shock, allow up to 20 minutes for capictors to discharge after isolating the mains supply before starting work on any high voltage modules.

When using solvents, wear suitable eye protection at all times. Ensure adequate ventilation to prevent buildup of vapour and work well away from possible sources of ignition.

Instructions on replacing the 629686Xx Analogue Power Supply.

Instructions on replacing the 629683Xx Digital Power Supply.

Instructions on replacing the 629924Xx Fader & Fader driver assembly.

Instructions on replacing the 629992Xx Solo & Cuts panel.

Instructions on replacing the 629992Xx and 629994 channel strip assemblies.

Instructions on replacing the 629923Xx Channel Meters assembly.

Instructions on replacing the 629925Xx Motion Control Panel.

Instructions on replacing the 629926Xx Monitor Control Panel.

Instructions on replacing the 629927Xx Workstation Control Panel.

Instructions on replacing the 629651Xx 6-Track Select ,629652Xx 2-Track Select , 629653Xx Monitor gain & MDAC control and 629654Xx Monitor Outputs assemblies.

Instructions on replacing the 629928Xx Buss Compressor assembly.

Instructions on replacing the 629918X1 Cue&FX Sends, 629918X2 Track Buss Masters, 629919X1 and 629919X2 Dynamics assemblies.

CPU

Instructions on replacing the 629675Xx CPU assembly.